Fix Raid on LSI controllers when a disk is shown as ubad

This can be done with both megacli and storcli.

Since the way forward is storcli this how to will be based on that.

 

storcli /c0 show all

 

Drive Information :
=================
 
-------------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model                  Sp 
-------------------------------------------------------------------------------
8:1       7 Onln   0  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
8:2       6 Onln   0  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
8:3       5 Onln   0  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U
.
.
8:14      4 UBad   - 223.062 GB SATA SSD N   N  512B INTEL SSDSC2CW240A3    U  
-------------------------------------------------------------------------------

 

Say 8:14 is marked a Ubad. (Unconfigured bad)

storcli /c0 /e8 /s14 set good

storcli /c0 show all

It should now have the disk marked as Ugood ( Unconfigured Good)

-------------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model                  Sp 
-------------------------------------------------------------------------------
8:1       7 Onln   0  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
8:2       6 Onln   0  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U  
8:3       5 Onln   0  465.25 GB SATA HDD N   N  512B WDC WD5003ABYX-01WERA1 U
.
.
8:14      4 uGood  F 223.062 GB SATA SSD N   N  512B INTEL SSDSC2CW240A3    U  
-------------------------------------------------------------------------------

storcli /c0 -/fall show

 

Controller = 0
Status = Success
Description = Operation on foreign configuration Succeeded
 
 
FOREIGN CONFIGURATION :
=====================
 
----------------------------------------
DG EID:Slot Type State       Size NoVDs 
----------------------------------------
 F -        Cac0 Frgn  223.062 GB     1 
----------------------------------------
 
NoVDs - Number of VDs in disk group|DG - Diskgroup
Total foreign drive groups = 1

 

This would show an external configuration which needs clearing.

Now we need to clear the config data from the previous RAID conf cached on the disk.

 

storcli /cx /fall import

 

This will clear the foreign config and start the rebuild.

 

To follow the rebuild :

 

storcli /c0 /e8 /sall show rebuild 
Controller = 0
Status = Success
Description = Show Drive Rebuild Status Succeeded.
———————————————————
Drive-ID Progress% Status Estimated Time Left
———————————————————
/c0/e8/s0 – Not in progress –
/c0/e8/s1 – Not in progress –
/c0/e8/s2 – Not in progress –
/c0/e8/s3 – Not in progress –
/c0/e8/s4 – Not in progress –
/c0/e8/s5 – Not in progress –
/c0/e8/s6 – Not in progress –
/c0/e8/s7 – Not in progress –
/c0/e8/s8 – Not in progress –
/c0/e8/s9 – Not in progress –
/c0/e8/s10 – Not in progress –
/c0/e8/s11 – Not in progress –
/c0/e8/s12 – Not in progress –
/c0/e8/s13 – Not in progress –
/c0/e8/s14 93 In progress –
/c0/e8/s15 – Not in progress –
———————————————————

 

Or for one drive in particular:

 

storcli /c0 /e8 /s14 show rebuild

Controller = 0
Status = Success
Description = Show Drive Rebuild Status Succeeded.
———————————————————————————————————-
Drive-ID          Progress% Status            Estimated Time Left
———————————————————————————————————-
/c0/e8/s14       93               In progress –
———————————————————————————————————-

 

That’s it.

 

[ NOTE : ]   Rebuild might take more than 1 day in default mode…. Just saying be patient.

 